Our company recommends you to choose vector control algorithms to manage motors and get the maximum performance in your applications.
The vector motor control uses two independent control loops to provide simultaneous control of motor speed and flux. A speed/torque loop for closed loop control of motor speed or shaft torque and a flux loop to provide constant magnetizing amps throughout the motor's speed range.
These control loops are capable of providing:
| |
» Tight Speed Regulation - 0.05% steady state error.
» Direct Torque Regulation - torque setpoint control from 0 to 100% rated torque.
» Control at Zero Speed - generate 150% torque for high breakaway torque applications.
» High Dynamic Response - 15 Hz bandwidth response is ideal for rapid load changes |

|